Checkline DT-209X Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Urządzenia pomiarowe Checkline DT-209X. Checkline DT-209X User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 2

6FULL Full memory indicator (the unit cannot store additional data) CCCCC Clear data from memory. Holding memory button for 5 seconds will clear s

Strona 3 - Table of Contents

7 Measurement Mode The Measurement Mode is changed with the Measurement Mode Selector switch. There are three basic settings USB, Standard and

Strona 4

8Average mode • The max, min, average, last and time of measurement can be stored in memory via power button. • The unit can store a maximum of 30

Strona 5

9Average Mode USB Mode Online measurements, software controlled programs can run and take measurements while the

Strona 6 - Measurement

10Measuring Methods Rotational speed measurement (Contact RPM) Example: RPM measurement using the cone tip for motor rotation. The contact adapt

Strona 7 - Rotation Speed

11Three decimal points will flash on the center of the display when the tachometer is out of range. Speed and Length Measurements Example: Length me

Strona 8 - For rotational

12Typical measurement update is 1 second. (Using the software the update time can be adjusted as fast as 0.5 second). Things to Remember The rub

Strona 9

13 CAUTION: Do not look into the laser beam opening while in operation. Staring into the laser beam can result to eye damage. The power switch i

Strona 10 - rEAdy

14 Pressing the Power Switch it will show the memory block number where readings will be stored. The block number will flash for a few seconds. (Me

Strona 11

15The memory location where the measurement will be stored is shown on the Unit and Measurement section of the LCD display. (“M” followed by the num

Strona 12

Thank you for your purchase of this Tachometer Product. This manual explains how to operate your equipment safely and correctly. The manual covers

Strona 13

162. Average Mode Average mode is displayed on the LCD screen Pushing the Power Switch will show the memory block number where reading

Strona 14

17 Releasing the Power Switch will trigger the auto shut off feature to activate. 3. USB Mode The Measurement Mode Selector Switch is set

Strona 15

18 To recall memory from the DT-209X, the memory button is pressed and then released. The last measured value is displayed. The Memory Button

Strona 16

19The stored data in the tachometer can be recalled each time the memory button is pressed (M1→M2 etc.). (This is only applicable to the last Memory

Strona 17

20 The Memory Button is pressed and then released. The minimum measured value is displayed. The memory button is pressed and then released.

Strona 18

21 Clearing all the stored memory blocks requires manual deletion from the tachometer. (Example: To clear 23 blocks of memory requires erasing th

Strona 19

22LO BAT Maximum Values Allowed Unit Full range Unit Full range Non contact RPM 99,999 Contact RPM 25,000 m/min 3810.0 yd/min 4617.0 ft/min 12,50

Strona 20

23Specifications Content Model DT-209X (6-inch cir wheel), DT-209X-S12 (12-inch cir wheel) Standard mode Measurement with memory switch Average m

Strona 23

DT-209X Handheld Digital Laser Tachometer Table of Contents Section I – Handheld Tachometer • Description of Parts………………………………………………………………………….

Strona 25

DT-209X API Section Thank you for your purchase of the DT-209X handheld tachometer. Please read this section carefully before using the DT-209X soft

Strona 26 - 9999.9

Observe caution when using this software and mounting the tachometer. Serious damage to equipment is possible when misused. DT-209X API Manual CD

Strona 27

DT-209X USB Driver Installation: (WINDOWS XP) Included in your package is a USB cable. Attach USB cable to the handheld tachometer and host computer a

Strona 28

Click next. Installation process will continue. After installation is completed the following window will be displayed. Cl

Strona 29

Browse the CD content. Go to PC_API folder Windows installer package Select Windows installer package to

Strona 30

DT-209X set up wizard will open. Click “Next>” Choose installation folder where DT-209X program will be stored. 32

Strona 31

Disk Cost Space availability. Browse • Allows users to select location of the application • Default set up: C: \Program Files\NIDEC-SHIMPO\DT-20

Strona 32

Set up wizard will start the installation process. Please allow a few minutes to complete the installation process.

Strona 33

DT-209X Application Software Read this section carefully as it holds important information regarding the DT-209X software and mode windows operation

Strona 35

Main Screen Description 1. Exit – terminates the program and exits the software 2. USB Mode – Online measurement (Note: Make sure that the DT

Strona 36

5. Time Synchronize - Synchronize time with host computer for generating time stamping reports. To activate this feature click on time synchronize

Strona 37

Example: In Non-contact RPM Maximum expected speed is 1,000 RPM. Entering 1,000 in the programmable analog output will scale 1V from 0 to 1000 rpm.

Strona 38

Virtual Software LCD Display Troubleshooting USB Communication • If USB communication cannot be establish check USB cable from the tachomete

Strona 39 - DT209X for PC Windows.lnk

Unit Selector (Software) Selecting units of measure can be changed easily from the software. Provided on the main window is a virtual copy of the

Strona 40

USB Mode Screen USB mode screen display explanation Make sure that the DT-209X handheld tachometer is set to USB mode on the selector switch. Any

Strona 41

Files are saved in CSV format, which can be opened by spreadsheets. Sample of data opened in Microsoft Excel (USB Mode). Example: T

Strona 42

Sample of data saved in Excel (Standard Mode). 3. Restore – file retrieval button. Open saved file fro

Strona 43

File restore window The letter “R” identifies file restored on the list of data shown from the screen. 4. Start - measurement st

Strona 44

5. Print – Print function from the software allows transfer of images displayed from the screen to a local printer. Keystroke shortcut “ALT + P”. 6

Strona 45

1 Model DT-209X casing is similar to standard DT-207/DT-205L with addition of USB port, analog output, and selector switch. DT-209X Part

Strona 46

Confirmation screen, indicating unselected data will be erased 9. Graph – Opens graph in another window, only available in USB mode.

Strona 47

Example: The start trigger is set to 10,000. The tachometer will only start recording values when measurements exceed 10,000.

Strona 48

13. Maximum, Minimum, and Mean Value – The maximum, minimum and mean value are displayed based from the recorded data on the table.

Strona 49

15. Start and End – Displays the beginning and the end of measurements. Format: Month/ Day/ Year Time based on 24 Hours: Hour/Min/Seconds

Strona 50

18. Time – Displays synchronized time from the host computer. Format: Month/Day/Year followed by Time: Hour/Minutes Before testing it is adv

Strona 51

USB Mode Graph Screen This section describes the parts and functions of the Graph Screen under USB mode. 10 987654321 1. Cl

Strona 52

4. All – horizontal display control, time axis. Setting Explanation All It automatically sets time present while the measurements are in progres

Strona 53

Standard Mode Screen Explanation of the Standard mode screen: In this mode data can be downloaded from the DT-209X memory. Memory tab separates ea

Strona 54

1. Main – returns to the main screen (Shortcut keystroke ALT + M). 2. File Save – Downloaded data from the DT-209X is saved in CSV format. (Shortcu

Strona 55

55is selected the stored data from the DT-209X is cleared. No eval of previously stored data is possible. Selecting Cancel exits evice memory function

Strona 56

2 Parts Function 1 USB Connector Mini-USB connector for PC online measurements and data downloads. 2 Analog Output Connector 0 to 1-volt analog outp

Strona 57

7. Measurement Data – measured values stored in each memory block is displayed. 8. Block Tab – Memory block separation. Each tab corresponds to a

Strona 58

Average Mode Screen verage mode screen description and explanation. Average Mode screen initial window prior to download A Average Mode

Strona 59

1. Main – returns to the main screen. (Shortcut Keystroke ALT + M) 2. File Save – Saves downloaded data from the tachometer. File save button is ina

Strona 60

Restore File Window 4. Download – download saved data from the DT-209X. All blocks are displayed based from their occurrence. (Keystroke

Strona 61

Once “OK” is s 7. ata ane begi changes ased ormat H 8. ax, Min, A elected from the list. elected, all the Av

Strona 62

9. Blocks – Displays number of memory blocks downloaded from the tachometer. 10. HH:MM:SS. time when the data is accessed from the tachometer.

Strona 63

62 Display Hold: This feature is an enhancement to the DT-209X software, designed for users hich requires the ability to limit the amount of time the

Strona 64

ooting SectionTroublesh Problems Solution Software would not start, “Start” button anCheck mode selector switcd “Download” h. Set to USB MODE.

Strona 65

Measured value is divided by 2 There are two versions of the DT-209X, Standard Version DT-209X is set for 6 inch circumference wheel, and DT-209X-S12

Strona 66

3 Non-Contact Rotation Speed Measurement RPM Non- USB Mode(No cable connected) ON and OFF switch and block separator. For standard and average m

Strona 67

4Unit Selector Switch Multi-mode capability measures RPM, mPM, YPM, FPM, IPM and total meters, yards, feet and inches. NOTE: Select

Strona 68

5 Operation • The switch selector can be turned clockwise or counter-clockwise depending on which unit of measure is required. • The unit of measu

Komentarze do niniejszej Instrukcji

Brak uwag