–1 –TABLE OF CONTENTS01.0 Introduction ...
–10 –6.1 Memory Mode Selection1. Switch on the tension meter2. Clear the memory by simultaneously pressing the MEM and RECALL keys.3. Press a
–11 –To Stop Data Logging:1. When you want to stop data logging, press the MEM key once again. The statistical values are calculated from the logged
– 12 –The MEM Mem indicator is frozen on the DISPLAY and the current reading is displayed. The tension meter has changed back to measuring mode.To Sav
–13 –To Save The Next Measuring Period:1. Press the MEM key again. The DISPLAY shows the memory mode “S” and the next memory number.6.5 Data Loggin
–14 –7.0 RECALLING TENSION VALUES STORED IN MEMORYUsing the Tension Inspect software, you can easily and accurately evaluate the stored tension values
–15 –7.2 Recalling Stored Values in Mode C (Continuous)1. Turn on the tension meter and press the RECALL key, You can exit recall at any time b
–16 –7.3 Recalling Stored Values in Mode L (Limit)1. Turn on the tension meter and press the RECALL key, You can exit recall at any time by pre
–17 –7.4 Recalling Stored Values in Mode F (Fast)1. Turn on the tension meter and press the RECALL key, You can exit recall at any time by pres
–18 –7.5 Clearing the MemoryIf values are stored in the memory, the DISPLAY shows the MEM indicator.To clear the memory:Simultaneously press the ME
ELECTROMATIC E Q U I P M E N T C O., I N C.600 Oakland Ave., Cedarhurst, NY 11516 – USA TEL: 516-295-4300 • FAX: 516-295-4399CHECK•LINE®INSTRU
– 2 – 1.0 INTRODUCTIONThree long, closely-spaced slender shafts with precision guide rollers or pins attheir ends combine with the latest in micropr
– 3 –2.0 OVERVIEW2.1 Operating Elements6 DAMP key7 LEVER8 FILAMENT GUIDE9 INTERFACE1 ROLLERS or ceramic pins2 DISPLAY3 POWER / ZERO key4 MEM ke
– 4 –2.3 Turning the Power On and OffPower On: Press the POWER key until the DISPLAY momentarily shows the tension range and the software version, e
– 5 –2.6 Zero Adjustment of the Measuring Position (Auto Zero)A Zero Adjustment is automatically carried out for the current measuring postion.A Zer
– 6 –3.0 REMOVING AND REMOUNTING THE FILAMENT GUIDEThe tension meter is supplied with a FILAMENT GUIDE for fast and easy material acquisition. For ap
– 7 –4.0 TAKING A MEASUREMENTNOTE: Before taking a measurement, be sure that the correct unit of measurement ( g or cN) has been selected and a zero
– 8 –5.0 DAMPING MODEThe tension meter is equipped with an electronic damping that ensures steady readings when tension ucutates. This is achieved by
– 9 –6.0 MEMORY MODEThe tension meter features a data logger with a memory capacity for up to 4000 readings, with which you can store different measur